Water heaters
SPC Plus
Air-source monobloc heat pump water heaters
READ MOREHeat pump technology that allows domestic hot water production whilst maintaining optimum home comfort, a short tank charging time and high efficiency.
SPC Plus consists of 200 and 250-litre floor standing models with or without additional exchanger, suitable for applications demanding high volumes of domestic hot water at temperatures up to 65°C, minimum energy consumption and eco-friendly R290 gas (GWP= 3, tCO2eq =0).
Heat pump technology that allows domestic hot water production whilst maintaining optimum home comfort, a short tank charging time and high efficiency.
SPC Plus consists of 200 and 250-litre floor standing models with or without additional exchanger, suitable for applications demanding high volumes of domestic hot water at temperatures up to 65°C, minimum energy consumption and eco-friendly R290 gas (GWP= 3, tCO2eq =0).
![](https://international.baxi.it/storage/app/media/Products/Water-heaters/spc-plus/spc-plus-1.jpg)
![](https://international.baxi.it/storage/app/media/Products/Water-heaters/spc-plus/spc-plus-2.jpg)
![](https://international.baxi.it/storage/app/media/Products/Water-heaters/spc-plus/spc-plus-3.jpg)
Characteristics
- Domestic hot water production up to 65°C
- Operates with external air from -7 °C to +42 °C
- R290 refrigerant gas (low GWP = 3)
- Electrical back up 1,8 kW
- Reduced electric consumption: only 450 W
- Model with solar or boiler system integration (SPC 200 S Plus and SPC 250 S Plus)
- Compact dimensions, height less than 1800 mm
- Connection for PV integration
- Easy-to-read display
- Schedule management and consumption monitoring
- Sanitary recirculation option (SPC 200 S Plus and SPC 250 S Plus)
- Anti-legionella function
- Electrical-pulse titanium anode
details
Capacity l
196, 188, 251, 243
destination
Residential
mounting
Floor standing monobloc
Capacity l
196, 188, 251, 243
destination
Residential
mounting
Floor standing monobloc
Features
![](https://international.baxi.it/storage/app/media/features/baxi-space.png)
baxi space
Advanced system control for a smart integration of different technologies. It offers a customized and efficient system tailored to meet all your needs and preferences
![](https://international.baxi.it/storage/app/media/features/digitalready.png)
digital ready
It can be connected to BaxiMAGO, the WI-FI smart modulating thermostat, and Baxi service App. You can have your boiler always under control
Smart Grid
It matches the supply and demand of electricity in real time, saving money on the energy bill
65°C
This product can produce hot water up to 65°C, without any other accessories required (such as immersion resistance)
R290
R290 is a gas featuring low GWP (3) and zero ODP, meaning it has a limited impact on the environment, electricity consumption and costs
Domestic hot water
This product allows the DHW production
PV connection
The connection for PV integration allows to exploit the energy from renewable sources, with further savings and overall system efficiency
![](https://international.baxi.it/storage/app/media/features/baxi-space.png)
Advanced system control for a smart integration of different technologies. It offers a customized and efficient system tailored to meet all your needs and preferences
![](https://international.baxi.it/storage/app/media/features/digitalready.png)
It can be connected to BaxiMAGO, the WI-FI smart modulating thermostat, and Baxi service App. You can have your boiler always under control
It matches the supply and demand of electricity in real time, saving money on the energy bill
This product can produce hot water up to 65°C, without any other accessories required (such as immersion resistance)
R290 is a gas featuring low GWP (3) and zero ODP, meaning it has a limited impact on the environment, electricity consumption and costs
This product allows the DHW production
The connection for PV integration allows to exploit the energy from renewable sources, with further savings and overall system efficiency
Technical Specification
models | SPC 200 Plus | SPC 200 S Plus | SPC 250 Plus | SPC 250 S Plus | |
---|---|---|---|---|---|
ErP data | |||||
Load profile | L | L | XL | XL | |
Energy efficiency for DHW ŋwh (3) | % | 128% | 130% | 143% | 135% |
Rated heat output (1) | kW | 1,35 | 1,34 | 1,32 | 1,3 |
Absorbed electrical power (1) | kW | 0,44 | 0,43 | 0,38 | 0,4 |
COP (1) | 3,09 | 3,15 | 3,48 | 3,28 | |
Rated heat output (2) | kW | 1,46 | 1,48 | 1,45 | 1,41 |
Absorbed electrical power (2) | kW | 0,45 | 0,44 | 0,4 | 0,4 |
COP (2) | 3,25 | 3,33 | 3,63 | 3,54 | |
Performance | |||||
Electrical back-up output | kW | 1,8 | 1,8 | 1,8 | 1,8 |
Exchanger surface | m2 | - | 0,93 | - | 0,93 |
Loading time (1) | 6h 33m | 6h 29m | 8h 56m | 8h 37m | |
Loading time - BOOST MODE (1) | 3h 02m | 3h 57m | 2h 57m | 3h 49m | |
Heat losses | kWh/24h | 1,01 | 0,97 | 1,23 | 1,19 |
Maximum working pressure | bar | 10 | 10 | 10 | 10 |
Air flow rate (1) | m3/h | 380 | 380 | 380 | 380 |
Available air pressure | Pa | 50 | 50 | 50 | 50 |
Maximum DHW temperature * | °C | 65 | 65 | 65 | 65 |
40 °C mixing water volume | l | 254 | 338 | 249 | 320 |
Min/max outdoor temperature (with ducting) | °C | -7/+42 | -7/+42 | -7/+42 | -7/+42 |
Dimension | |||||
Storage volume | l | 196 | 188 | 251 | 243 |
Air duct diameter | mm | 160 | 160 | 160 | 160 |
Maximum length of the air duct (inlet and outlet) | m | 20 | 20 | 20 | 20 |
Miminum volume of the installation room (with ducting) | m3/h | 10 | 10 | 10 | 10 |
Miminum volume of the installation room (without ducting) | m3/h | 17 | 17 | 17 | 17 |
Refrigerant fluid | R290 | R290 | R290 | R290 | |
Refrigerant fluid R513A / Equivalent CO2 | kg - tCO2e | ||||
Refrigerant fluid R290 / Equivalent CO2 | kg - tCO2e | 0 | 0 | 0 | 0 |
Sound power, Lwa | dB(A) | 49 | 49 | 49 | 49 |
Power supply | V/Ph/Hz | 230/1/50 | 230/1/50 | 230/1/50 | 230/1/50 |
Dimensions (h x d) | mm | 1528 x 667 | 1528 x 667 | 1760 x 667 | 1760 x 667 |
Empty weight | kg | 88 | 102 | 99 | 113 |
models | SPC 200 Plus | SPC 200 S Plus | SPC 250 Plus | SPC 250 S Plus | |
---|---|---|---|---|---|
ErP data | |||||
Load profile | L | L | XL | XL | |
Energy efficiency for DHW ŋwh (3) | % | 128% | 130% | 143% | 135% |
Rated heat output (1) | kW | 1,35 | 1,34 | 1,32 | 1,3 |
Absorbed electrical power (1) | kW | 0,44 | 0,43 | 0,38 | 0,4 |
COP (1) | 3,09 | 3,15 | 3,48 | 3,28 | |
Rated heat output (2) | kW | 1,46 | 1,48 | 1,45 | 1,41 |
Absorbed electrical power (2) | kW | 0,45 | 0,44 | 0,4 | 0,4 |
COP (2) | 3,25 | 3,33 | 3,63 | 3,54 | |
Performance | |||||
Electrical back-up output | kW | 1,8 | 1,8 | 1,8 | 1,8 |
Exchanger surface | m2 | - | 0,93 | - | 0,93 |
Loading time (1) | 6h 33m | 6h 29m | 8h 56m | 8h 37m | |
Loading time - BOOST MODE (1) | 3h 02m | 3h 57m | 2h 57m | 3h 49m | |
Heat losses | kWh/24h | 1,01 | 0,97 | 1,23 | 1,19 |
Maximum working pressure | bar | 10 | 10 | 10 | 10 |
Air flow rate (1) | m3/h | 380 | 380 | 380 | 380 |
Available air pressure | Pa | 50 | 50 | 50 | 50 |
Maximum DHW temperature * | °C | 65 | 65 | 65 | 65 |
40 °C mixing water volume | l | 254 | 338 | 249 | 320 |
Min/max outdoor temperature (with ducting) | °C | -7/+42 | -7/+42 | -7/+42 | -7/+42 |
Dimension | |||||
Storage volume | l | 196 | 188 | 251 | 243 |
Air duct diameter | mm | 160 | 160 | 160 | 160 |
Maximum length of the air duct (inlet and outlet) | m | 20 | 20 | 20 | 20 |
Miminum volume of the installation room (with ducting) | m3/h | 10 | 10 | 10 | 10 |
Miminum volume of the installation room (without ducting) | m3/h | 17 | 17 | 17 | 17 |
Refrigerant fluid | R290 | R290 | R290 | R290 | |
Refrigerant fluid R513A / Equivalent CO2 | kg - tCO2e | ||||
Refrigerant fluid R290 / Equivalent CO2 | kg - tCO2e | 0 | 0 | 0 | 0 |
Sound power, Lwa | dB(A) | 49 | 49 | 49 | 49 |
Power supply | V/Ph/Hz | 230/1/50 | 230/1/50 | 230/1/50 | 230/1/50 |
Dimensions (h x d) | mm | 1528 x 667 | 1528 x 667 | 1760 x 667 | 1760 x 667 |
Empty weight | kg | 88 | 102 | 99 | 113 |
* Maximum DHW temperature with heat pump only. Maximum water temperature with electric resistance = 75 °C.
(1) According to EN 16147: air temperature = 7 °C, water inlet temperature = 10 °C, DHW temperature = 55 °C
(2) According to EN 16147: air temperature = 14 °C, water inlet temperature = 10 °C, DHW temperature = 55 °C
(3) Average climatic conditions
Benefits
![](https://international.baxi.it/themes/baxi//assets/images/product/durability.jpg)
reliability
Consistent performance over time in all conditions and long-lasting components
![](https://international.baxi.it/themes/baxi//assets/images/product/efficiency.jpg)
efficiency
Our products are designed for an effective use of energy and to achieve optimal performance
![](https://international.baxi.it/themes/baxi//assets/images/product/italian.jpg)
italian design
A combination of elegance, tradition and innovation
![](https://international.baxi.it/themes/baxi//assets/images/product/connectivity.jpg)
complete offer
We offer affordable, complete and tailor-made solutions for every customer
![](https://international.baxi.it/themes/baxi//assets/images/product/comfort.jpg)
comfort
We care about your comfort: feel good at your home!
![](https://international.baxi.it/themes/baxi//assets/images/product/a_class.jpg)
sustainability
Baxi is committed in reducing waste, energy-efficiency and eco-friendly production
![](https://international.baxi.it/themes/baxi//assets/images/product/durability_mobile.jpg)
durability
Simply strong and long lasting without
getting damaged.
![](https://international.baxi.it/themes/baxi//assets/images/product/efficiency_mobile.jpg)
efficiency
Simply strong and long lasting without
getting damaged.
![](https://international.baxi.it/themes/baxi//assets/images/product/italian_mobile.jpg)
italian design
It is not necessarily linked to luxury,
but it is fueled with taste.
![](https://international.baxi.it/themes/baxi//assets/images/product/connectivity_mobile.jpg)
connectivity
The Internet of Things let objects “talk”
to each other.
![](https://international.baxi.it/themes/baxi//assets/images/product/comfort_mobile.jpg)
comfort
Feeling good in your own space.
![](https://international.baxi.it/themes/baxi//assets/images/product/a_class_mobile.jpg)
a+ class / h2 ready
Sustainability and hydrogen are the
key factors to our future.
download area
Download file not available.