Ecofour has been designed for flats and small homes and for all situations when saving space is important. The compact dimensions allow the boiler to be easily located, including in a kitchen cupboard.

Easy to install, use and service, it perfectly matches classic single temperature zone heating systems and domestic hot water requirements.

Large, simple and easy to use LCD display for comfortable setting and control, with easy access to status informations and parametres. 

The brass hydroblock ensures long term reliable performance.

Ecofour has been designed for flats and small homes and for all situations when saving space is important. The compact dimensions allow the boiler to be easily located, including in a kitchen cupboard.

Easy to install, use and service, it perfectly matches classic single temperature zone heating systems and domestic hot water requirements.

Large, simple and easy to use LCD display for comfortable setting and control, with easy access to status informations and parametres. 

The brass hydroblock ensures long term reliable performance.

Characteristics
  • Compact dimensions (700x400x299 mm)
  • Brass hydroblock
  • Steel burner
  • Digital control panel with back-lit LCD display and dedicated push buttons
  • Enahnced primary exchanger made of copper pipes with anticorrosion coating
  • Stainless steel DHW heat exchanger
  • Low energy circulating pump with automatic air vent
  • Overheat limit thermostat for the water/flue exchanger
  • Hydraulic pressure switch to prevent boiler’s operating in event of low water

details

Power KW

24 F, 24, 1.24 F, 1.14 F, 1.24, 1.14

destination

Residential

mounting

Wall hung

Power KW

24 F, 24, 1.24 F, 1.14 F, 1.24, 1.14

destination

Residential

mounting

Wall hung

Technical Specification

models 24F 24 1.24F 1.14 F 1.24 1.14
Heat input/output
Maximum heat input kW 25,8 26,3 25,8 15,1 26,3 15,4
Minimum heat input kW 10,6 10,6 10,6 7,1 10,6 7,1
Maximum heat output kW 24 24 24 14 24 14
Minimum heat output kW 9,3 9,3 9,3 6 9,3 6
Efficiency at maximum output % 92,9 91,2 92,9 92,5 91,2 90,9
Temperature range for heating circuit °C 30/45 or 30/85 30/45 or 30/85 30/45 or 30/85 30/45 or 30/85 30/45 or 30/85 30/45 or 30/85
Water capacity of expansion vessel l 6 6 6 6 6 6
Temperature range for domestic water circuit °C 35/60 35/60 - - - -
DHW production ΔT 25°C l/min 13,7 13,7 - - - -
Specific flow according to EN 625 l/min 10,7 10,7 - - - -
Diameter of separate discharge pipes mm 80/80 - 80/80 80/80 - -
Diameter of coaxial discharge pipes mm 60/100 - 60/100 60/100 - -
Diameter of the flue tube mm - 120 - - 120 120
Flue gas mass flow rate (max) kg/sec 0,014 0,020 0,014 0,012 0,020 0,014
Flue gas mass flow rate (min) kg/sec 0,014 0,018 0,014 0,012 0,018 0,013
Power supply voltage V 230 230 230 230 230 230
Power supply frequency Hz 50 50 50 50 50 50
Humidity protection rating (EN 60529) IP X5D X5D X5D X5D X5D X5D
Dimensions (height/width/depth) mm 730x400x299 730x400x299 730x400x299 730x400x299 730x400x299 730x400x299
Gas type Natural gas/LPG* Natural gas/LPG* Natural gas/LPG* Natural gas/LPG* Natural gas/LPG* Natural gas/LPG*
Net weight kg 33 29 32 31 28 26

models 24F 24 1.24F 1.14 F 1.24 1.14
Heat input/output
Maximum heat input kW 25,8 26,3 25,8 15,1 26,3 15,4
Minimum heat input kW 10,6 10,6 10,6 7,1 10,6 7,1
Maximum heat output kW 24 24 24 14 24 14
Minimum heat output kW 9,3 9,3 9,3 6 9,3 6
Efficiency at maximum output % 92,9 91,2 92,9 92,5 91,2 90,9
Temperature range for heating circuit °C 30/45 or 30/85 30/45 or 30/85 30/45 or 30/85 30/45 or 30/85 30/45 or 30/85 30/45 or 30/85
Water capacity of expansion vessel l 6 6 6 6 6 6
Temperature range for domestic water circuit °C 35/60 35/60 - - - -
DHW production ΔT 25°C l/min 13,7 13,7 - - - -
Specific flow according to EN 625 l/min 10,7 10,7 - - - -
Diameter of separate discharge pipes mm 80/80 - 80/80 80/80 - -
Diameter of coaxial discharge pipes mm 60/100 - 60/100 60/100 - -
Diameter of the flue tube mm - 120 - - 120 120
Flue gas mass flow rate (max) kg/sec 0,014 0,020 0,014 0,012 0,020 0,014
Flue gas mass flow rate (min) kg/sec 0,014 0,018 0,014 0,012 0,018 0,013
Power supply voltage V 230 230 230 230 230 230
Power supply frequency Hz 50 50 50 50 50 50
Humidity protection rating (EN 60529) IP X5D X5D X5D X5D X5D X5D
Dimensions (height/width/depth) mm 730x400x299 730x400x299 730x400x299 730x400x299 730x400x299 730x400x299
Gas type Natural gas/LPG* Natural gas/LPG* Natural gas/LPG* Natural gas/LPG* Natural gas/LPG* Natural gas/LPG*
Net weight kg 33 29 32 31 28 26

*LPG operation with conversion kit

Benefits

reliability

Consistent performance over time in all conditions and long-lasting components

efficiency

Our products are designed for an effective use of energy and to achieve optimal performance

italian design

A combination of elegance, tradition and innovation

complete offer

We offer affordable, complete and tailor-made solutions for every customer

comfort

We care about your comfort: feel good at your home!

sustainability

Baxi is committed in reducing waste, energy-efficiency and eco-friendly production

durability

Simply strong and long lasting without
getting damaged.

efficiency

Simply strong and long lasting without
getting damaged.

italian design

It is not necessarily linked to luxury,
but it is fueled with taste.

connectivity

The Internet of Things let objects “talk”
to each other.

comfort

Feeling good in your own space.

a+ class / h2 ready

Sustainability and hydrogen are the
key factors to our future.

download area

Installation and Service Manual (en-es-ru)

Installation and Service Manual (ar-fr)

Installation and Service Manual (uk)

Installation and Service Manual (cn)

Get more details and information about Baxi products
find a dealer
Would you like to be our partner?
get in touch