High output gas condensing systems

Power HT+

Single or cascade centralized heating systems installations
READ MORE

The range of Power HT+ consists of floor-standing commercial condensing boilers, with output between 50 and 250 kW (50/30°C).

Power HT+ are heating only boilers for centralized systems with the possibility to be connected to a domestic hot water tank.

Cascade option for greater heating demand, up to 6 boilers.

The range of Power HT+ consists of floor-standing commercial condensing boilers, with output between 50 and 250 kW (50/30°C).

Power HT+ are heating only boilers for centralized systems with the possibility to be connected to a domestic hot water tank.

Cascade option for greater heating demand, up to 6 boilers.

Characteristics
  • Modulation up to 1:9 (1:5  models from 130 to 250 kW) reduces on-off cycles for improved efficiency and energy savings
  • Low water content heat exchanger for a rapid response to system heating demand
  • Large back-lit display
  • Stainless steel burner (metalic fiber for 1.110 model)
  • Adjustable fan speed and insulation for silent operation
  • Premixi air-gas unit ensures that the burner constantly has an optimal air/gas ratio, for better efficiency and lower energy consumption
  • Up to 6 boilers in cascade

details

Power KW

1.50, 1.70, 1.90, 1.110, 1.130, 1.150, 1.200, 1.250

destination

Commercial

mounting

Floor standing

Power KW

1.50, 1.70, 1.90, 1.110, 1.130, 1.150, 1.200, 1.250

destination

Commercial

mounting

Floor standing

Technical Specification

models 1.50 1.70 1.90 1.110 1.130 1.150 1.200 1.250
Heat input/output
Maximum heat input (heating) kW 46,3 66,9 87,4 104,9 123,8 143 191 240
Minimum heat output kW 5,1 7,4 9,7 11,7 24,8 28,6 31,8 40
Useful heat output at rated heat output and high temperature regime(2) P4 kW 45 65 85 102 121,5 140,3 185,9 232,8
Minimum heat output (80/60°C) kW 5 7,2 9,4 11,4 24,3 28,1 31 38,8
Maximum heat output (50/30°C) kW 48,6 70,2 91,8 110,2 130,6 150,9 200 250
Minimum heat output (50/30°C) kW 5,4 7,8 10,2 12,3 26,2 30,2 33,1 41,7
Useful heat output at 30% of rated heat output and low temperature setting(1) P1 kW 15 21,7 28,3 34 40,4 46,6 36 46
Seasonal space heating energy efficiency class*** A A - - - - - -
Useful efficiency at rated heat output and high temperature setting(2) ƞ4 % 87,7 87,6 87,7 87,6 88,4 88,4 87,7 87,4
Useful efficiency at 30% of rated heat output and low temperature setting(1) ƞ1 % 97,7 97,4 97,5 97,4 97,8 97,8 98,3 98,3
Space heating – Seasonal energy efficiency ƞs % 93 93 93 93 93 93 94 94
Maximum pressure heating circuit bar 4 4 4 4 6 6 6 6
Maximum inlet temperature heating circuit °C 85 85 85 85 85 85 85 85
Temperature range for heating circuit °C 25-80 25-80 25-80 25-80 25-80 25-80 25-80 25-80
Water content l 2,81 4,98 8,34 9,83 10 11 13 15
Diameter of separate discharge pipes mm 80-80 80-80 110-110 110-110 110-110 110-110 160-160 160-160
Diameter of coaxial discharge pipes mm 80-125 80-125 110-160 110-160 110-160 110-160 - -
Nitrogen oxide emissions NOx mg/kWh 27 31 36 22 17 23 37 39
Flue gas mass flow rate (max) kg/s 0,075 0,111 0,144 0,169 0,201 0,230 0,322 0,411
Flue gas mass flow rate (min) kg/s 0,007 0,014 0,018 0,018 0,043 0,050 0,054 0,069
Maximum flue temperature °C 92 76 70 70 70 70 80 80
Gas type Natural Gas/LPG Natural Gas/LPG Natural Gas/LPG Natural Gas/LPG Natural Gas/LPG Natural Gas/LPG Natural Gas/LPG Natural Gas/LPG
Rated power supply W 100 117 146 185 187 283 242 369
Auxiliary electrical power consumption - Full load elmax W 100 117 146 185 187 283 242 369
Auxiliary electrical power - Partial load elmin W 23 24 24 24 51 52 47 48
Auxiliary electrical power - Stand-by PSB W 3 3 3 3 3 4 4 4
Power supply voltage V 230 230 230 230 230 230 230 230
Power supply frequency Hz 50 50 50 50 50 50 50 50
Sound power level, indoor LWA dB 61 64 - - - - - -
Humidity protection rating (EN 60529) IP X1B X1B X1B X1B X1B X1B X1B X1B
Net weight kg 60 70 104 109 126 132 212 232
Dimensions (height/width/depth) mm 900x600x681 900x600x681 1221x600x681 1221x600x681 1221x600x681 1221x600x681 1238x600x1410 1238x600x1410

models 1.50 1.70 1.90 1.110 1.130 1.150 1.200 1.250
Heat input/output
Maximum heat input (heating) kW 46,3 66,9 87,4 104,9 123,8 143 191 240
Minimum heat output kW 5,1 7,4 9,7 11,7 24,8 28,6 31,8 40
Useful heat output at rated heat output and high temperature regime(2) P4 kW 45 65 85 102 121,5 140,3 185,9 232,8
Minimum heat output (80/60°C) kW 5 7,2 9,4 11,4 24,3 28,1 31 38,8
Maximum heat output (50/30°C) kW 48,6 70,2 91,8 110,2 130,6 150,9 200 250
Minimum heat output (50/30°C) kW 5,4 7,8 10,2 12,3 26,2 30,2 33,1 41,7
Useful heat output at 30% of rated heat output and low temperature setting(1) P1 kW 15 21,7 28,3 34 40,4 46,6 36 46
Seasonal space heating energy efficiency class*** A A - - - - - -
Useful efficiency at rated heat output and high temperature setting(2) ƞ4 % 87,7 87,6 87,7 87,6 88,4 88,4 87,7 87,4
Useful efficiency at 30% of rated heat output and low temperature setting(1) ƞ1 % 97,7 97,4 97,5 97,4 97,8 97,8 98,3 98,3
Space heating – Seasonal energy efficiency ƞs % 93 93 93 93 93 93 94 94
Maximum pressure heating circuit bar 4 4 4 4 6 6 6 6
Maximum inlet temperature heating circuit °C 85 85 85 85 85 85 85 85
Temperature range for heating circuit °C 25-80 25-80 25-80 25-80 25-80 25-80 25-80 25-80
Water content l 2,81 4,98 8,34 9,83 10 11 13 15
Diameter of separate discharge pipes mm 80-80 80-80 110-110 110-110 110-110 110-110 160-160 160-160
Diameter of coaxial discharge pipes mm 80-125 80-125 110-160 110-160 110-160 110-160 - -
Nitrogen oxide emissions NOx mg/kWh 27 31 36 22 17 23 37 39
Flue gas mass flow rate (max) kg/s 0,075 0,111 0,144 0,169 0,201 0,230 0,322 0,411
Flue gas mass flow rate (min) kg/s 0,007 0,014 0,018 0,018 0,043 0,050 0,054 0,069
Maximum flue temperature °C 92 76 70 70 70 70 80 80
Gas type Natural Gas/LPG Natural Gas/LPG Natural Gas/LPG Natural Gas/LPG Natural Gas/LPG Natural Gas/LPG Natural Gas/LPG Natural Gas/LPG
Rated power supply W 100 117 146 185 187 283 242 369
Auxiliary electrical power consumption - Full load elmax W 100 117 146 185 187 283 242 369
Auxiliary electrical power - Partial load elmin W 23 24 24 24 51 52 47 48
Auxiliary electrical power - Stand-by PSB W 3 3 3 3 3 4 4 4
Power supply voltage V 230 230 230 230 230 230 230 230
Power supply frequency Hz 50 50 50 50 50 50 50 50
Sound power level, indoor LWA dB 61 64 - - - - - -
Humidity protection rating (EN 60529) IP X1B X1B X1B X1B X1B X1B X1B X1B
Net weight kg 60 70 104 109 126 132 212 232
Dimensions (height/width/depth) mm 900x600x681 900x600x681 1221x600x681 1221x600x681 1221x600x681 1221x600x681 1238x600x1410 1238x600x1410

(1) Low temperature: return temperature (at boiler inlet) for condensing boilers 30°C, for low temperature boilers 37°C and for other heaters 50°C.
(2) High temperature setting means 60 °C return temperature at boiler inlet and 80 °C flow temperature at boiler outlet.
*** Products with nominal output >70 kW are not subjected to energy labelling according to ErP regulation

Benefits

reliability

Consistent performance over time in all conditions and long-lasting components

efficiency

Our products are designed for an effective use of energy and to achieve optimal performance

italian design

A combination of elegance, tradition and innovation

complete offer

We offer affordable, complete and tailor-made solutions for every customer

comfort

We care about your comfort: feel good at your home!

sustainability

Baxi is committed in reducing waste, energy-efficiency and eco-friendly production

durability

Simply strong and long lasting without
getting damaged.

efficiency

Simply strong and long lasting without
getting damaged.

italian design

It is not necessarily linked to luxury,
but it is fueled with taste.

connectivity

The Internet of Things let objects “talk”
to each other.

comfort

Feeling good in your own space.

a+ class / h2 ready

Sustainability and hydrogen are the
key factors to our future.

download area

Technical leaflet (en)

Get more details and information about Baxi products
find a dealer
Would you like to be our partner?
get in touch