Fan coils

Floor

Floor/ceiling fan coil terminals for heating/cooling
READ MORE

A floor/ceiling fan coil with a neat and innovative design, suitable for installation in all domestic environments thanks to a depth of just 129 mm: for this reason it can be wall-recessed or inserted in a false ceiling without impacting the available space. 

The air flow is modulated and therefore the sound level is imperceptible with a total absence of drafts, especially in the radiant version (R).

A floor/ceiling fan coil with a neat and innovative design, suitable for installation in all domestic environments thanks to a depth of just 129 mm: for this reason it can be wall-recessed or inserted in a false ceiling without impacting the available space. 

The air flow is modulated and therefore the sound level is imperceptible with a total absence of drafts, especially in the radiant version (R).

Characteristics
  • 5 models (200, 400, 600, 800 and 1000) available in 4 versions: floor, ceiling, built-in, floor/recessed with radiant effect
  • Just 129 mm depth
  • Low noise level
  • Low energy consumption and modulated air flow thanks to DC inverter motor fans
  • Modulating-speed smart touch panel (accessory available on request)
  • Hydraulic connections can be configured right or left

details

Air flow m3/h

146, 294, 438, 567, 663

destination

Residential

mounting

Floor/Ceiling

Air flow m3/h

146, 294, 438, 567, 663

destination

Residential

mounting

Floor/Ceiling

Features

Heating and cooling

A year-round comfort: you can heat your home in winter and cool it in summer, with one sole product

A year-round comfort: you can heat your home in winter and cool it in summer, with one sole product

Technical Specification

models 200 400 600 800 1000
Cooling capacity (1) kW 0,91 2,12 2,81 3,3 3,71
Sensible performance in cooling (1) kW 0,73 1,72 2,11 2,71 2,9
Water flow rate (1) l/h 157 365 483 568 638
Heating output (2) kW 9,1 9,2 19,1 21,2 23,3
Water flow rate (2) l/h 1,02 2,21 3,02 3,81 4,32
Water pressure drop (2) kPa 175 380 519 655 743
Battery water content l 9,1 9,2 19,1 21,2 23,3
Maximum operating pressure bar 0,47 0,8 1,13 1,46 1,8
Hydraulic connections inches 10 10 10 10 10
Maximum air flow rate (3) m3/h Eurokonus 3/4’’ Eurokonus 3/4’’ Eurokonus 3/4’’ Eurokonus 3/4’’ Eurokonus 3/4’’
Air flow rate at medium speed (AUTO mode) m3/h 146 294 438 567 663
Air flow rate at minimum ventilation speed m3/h 90 210 318 410 479
Maximum static pressure available Pa 49 118 180 247 262
Supply voltage V/ph/Hz 10 10 13 13 13
Electrical power consumption at max speed W 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
Absorbed current at max allowed conditions A 11 19 20 29 29
Electrical power consumption at min speed W 0,11 0,16 0,18 0,26 0,26
Sound power at max air flow dB(A) 5 4 6 5 5
Sound pressure at max air flow rate (4) dB(A) 51 53 54 55 57
Sound pressure at average air flow rate (4) dB(A) 41 42 44 46 47
Sound pressure at minimum air flow rate (4) dB(A) 33 34 34 35 38
Dimensions (hxwxd) mm 579 x 735 x 129 579 x 935 x 129 579 x 1135 x 129 579 x 1336 x 129 579 x 1536 x 129
Weight kg 17 20 23 26 29

models 200 400 600 800 1000
Cooling capacity (1) kW 0,91 2,12 2,81 3,3 3,71
Sensible performance in cooling (1) kW 0,73 1,72 2,11 2,71 2,9
Water flow rate (1) l/h 157 365 483 568 638
Heating output (2) kW 9,1 9,2 19,1 21,2 23,3
Water flow rate (2) l/h 1,02 2,21 3,02 3,81 4,32
Water pressure drop (2) kPa 175 380 519 655 743
Battery water content l 9,1 9,2 19,1 21,2 23,3
Maximum operating pressure bar 0,47 0,8 1,13 1,46 1,8
Hydraulic connections inches 10 10 10 10 10
Maximum air flow rate (3) m3/h Eurokonus 3/4’’ Eurokonus 3/4’’ Eurokonus 3/4’’ Eurokonus 3/4’’ Eurokonus 3/4’’
Air flow rate at medium speed (AUTO mode) m3/h 146 294 438 567 663
Air flow rate at minimum ventilation speed m3/h 90 210 318 410 479
Maximum static pressure available Pa 49 118 180 247 262
Supply voltage V/ph/Hz 10 10 13 13 13
Electrical power consumption at max speed W 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
Absorbed current at max allowed conditions A 11 19 20 29 29
Electrical power consumption at min speed W 0,11 0,16 0,18 0,26 0,26
Sound power at max air flow dB(A) 5 4 6 5 5
Sound pressure at max air flow rate (4) dB(A) 51 53 54 55 57
Sound pressure at average air flow rate (4) dB(A) 41 42 44 46 47
Sound pressure at minimum air flow rate (4) dB(A) 33 34 34 35 38
Dimensions (hxwxd) mm 579 x 735 x 129 579 x 935 x 129 579 x 1135 x 129 579 x 1336 x 129 579 x 1536 x 129
Weight kg 17 20 23 26 29

(1) Water temperature 7/12°C, air temperature 27°C BS and 19°C BU according to EN 1397
(2) Water temperature 40/45°C, air temperature 20°C BS and 15°C BU according to EN 1397
(3) Air flow rate measured with clean filters
(4) Sound pressure measured at a distance of 1 meter according to ISO7779

Benefits

reliability

Consistent performance over time in all conditions and long-lasting components

efficiency

Our products are designed for an effective use of energy and to achieve optimal performance

italian design

A combination of elegance, tradition and innovation

complete offer

We offer affordable, complete and tailor-made solutions for every customer

comfort

We care about your comfort: feel good at your home!

sustainability

Baxi is committed in reducing waste, energy-efficiency and eco-friendly production

durability

Simply strong and long lasting without
getting damaged.

efficiency

Simply strong and long lasting without
getting damaged.

italian design

It is not necessarily linked to luxury,
but it is fueled with taste.

connectivity

The Internet of Things let objects “talk”
to each other.

comfort

Feeling good in your own space.

a+ class / h2 ready

Sustainability and hydrogen are the
key factors to our future.

download area

Download file not available.

Get more details and information about Baxi products
find a dealer
Would you like to be our partner?
get in touch